Model:JLY-600
Type: Halogen Leak Detector
Download: 1、JLY-600 Instruction 2、Acrobat Reader
Other: Feedback Concact Us
Main Functions :General informatione:
Incorporatede with advanced leak detect technology ,JLY-600 is our new product with the functions of easy operation ,stable function and small appearance,it’s an ideal and economic halogen leak detector.
Features:
◆Detect all kinds of halogen refrigerants.
◆Sensitibity adjusted at any time and it can be adjusted automatically to the best state of detecting.
◆Inner precise IC with Ultra-Low power consume circuit desing,more stable,longer battery time.
◆Excellent sensor,high sensibity,longer use time.
Reset Feature/Automatic Circult:
JLY-600 features on automatic circuit and a reset function that set the unit to ignore ambient concentrations of Halogen.
◆Reset:When power on ,the unit automatically sets itself to ignore the refrigerant level which is already in the tip in 6’s and enter into the best state of detecting .If place the sensing tip near a known leak place and switch the unit on ,it’s convinent to find higher concentration leak .Or move to fresh air and switch on ,adjust to maximum sensitivity,and concentration above zero will be detected.
◆Automatic-trace circuit:When in the measuring state,automatic-trace circuit willfollow the changing concentration of halogen gases in environment to avoid false alarm.
Adjustment of sensitivity:
The unit features vari-speed sensitivity adjustment and can be adjusted during the process of detecting .Clockwise adjusting means higher sensitivity,and Anti-Clockwise adjusting means lower sensitivity.
It does not mean ,when to select,the higher sensitivity is adjusted,the tetter the unit will work,because if the air is not fresh ,selecting higher sensitivity will cause an improper alarm.
Leak alarm:
When the leaked gas is decteted ,the audible tone will change to a “siren” type sound.More refrigerant more siren .At the same time ,indicator light is flashing quickly.
Applicationgs:
The JLY-600 may also be used to :
◆Detect leaks in other systems and storage/recovery containers .It will respond to All halogenated(contains Chlorine of Fluorine)refrigerants.
This includes,but is not limited to :
CFCs e.g.R12,R500,R503 etc…
HCFCs e.g.R22,R123,R124,R125 etc…
HFCs e.g.R134a,R404a,R125 etc…
Blends such as AZ-50.HP62.MP39 etc…
◆Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas)
◆Detect SF-6 in high voltage circuit breakers.
◆Detect most gases that contain chlorine ,Fluorine and Bromine(halogen gases).
◆Detect cleaning agents used in dry cleaning applications such as perchloroethy.
◆Detects halogen gases in fire-exting guishing system.
Specifications and parameter:
◆Operating temperature:0℃ to 52℃(30℉ to 125℉)
◆Maximum sensitivity:6gr/yr,for all halogenated refrigerants.
◆Battery life:Approximately 50 hours under normal use.
◆Response time :instant.
◆Fixed Probe Length:20cm
◆Unit Dimensions:22.9×6.5×6.5(cm)
◆Warm-up time:Approximately 6 seconds.
◆Reset Time:Two to ten seconds.
◆Power Supply:6V DC ,four cell 7# excellent batteries.
|